Electrical stimulation of the lower eyelid orbicularis oculi muscle improves periocular dark circles

Author:

Yasui Yukiko1ORCID,Kato Hiroshi1,Ogura Shuntaro2,Kimura Masayo2,Kato Aki2ORCID,Hirano Yoshio2,Morita Hiroshi2,Yasukawa Tsutomu2,Kurachi Ako3,Takeda Soshi3,Morita Akimichi1

Affiliation:

1. Department of Geriatric and Environmental Dermatology Nagoya City University Graduate School of Medical Sciences Nagoya Japan

2. Department of Ophthalmology and Visual Science Nagoya City University Graduate School of Medical Sciences Nagoya Japan

3. MTG Co. Ltd Nagoya Aichi Japan

Abstract

AbstractBackgroundWe developed and tested the safety and efficacy of a cosmetic device to improve dark circles using electrical muscle stimulation of the orbicularis oculi muscle.MethodsOverall, 18 participants (36 eyes) were studied. The following five items were evaluated before and after the intervention:(1) the Clinical Dark Circle Score using clinical findings and photographs, (2) transcutaneous oxygen partial pressure (TcPO2) on the lower eyelid, (3) thermography, (4) two‐dimensional laser blood flowmetry, and (5) spectrophotometry.ResultsThe mean score at baseline was 2.0 ± 0.90 (mean ± standard deviation), and that at the end of the study was 1.2 ± 1.0 (Wilcoxon signed‐rank sum test, p < 0.0001), indicating a significant reduction. The spectrophotometer showed a significant decrease in a* and L* values before and after use (Wilcoxon signed‐rank sum test, p < 0.0001). There was also a weak negative correlation between the change in score and the change in blood flow and TcPO2 measured using a laser perfusion device (Spearman's rank correlation coefficient, r = –0.32 and –0.39, respectively). Stratified analysis of the baseline score showed a strong negative correlation between the change in score and the change in spectrophotometric a* in the subjects/group with mild periocular dark circles (Spearman's rank correlation coefficient, r = –0.46). Contrastingly, no correlation was observed for any of the measurements in the subjects/group with severe periocular dark circles. After 1 month, no device‐related ophthalmic adverse events were observed in any of the participants.ConclusionElectrical muscle stimulation could improve periocular dark circles, especially in the subjects/group with mild periocular dark circles, and was safe.

Funder

Nagoya City University

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3