Effect of prefabricated immediate interim prosthesis design and insertion workflow on seating accuracy on implants placed via static computer‐assisted implant surgery: A cross‐sectional in vitro study

Author:

Abduo Jaafar1ORCID,Lau Douglas1

Affiliation:

1. Melbourne Dental School Melbourne University Melbourne Victoria Australia

Abstract

AbstractBackgroundImmediate implant restoration by prefabricated prosthesis has multiple benefits. However, the design and insertion workflow of the prosthesis may influence the seating.PurposeEvaluation of seating accuracy of prefabricated interim prosthesis of different designs and insertion workflows for immediate restoration of implants placed via static computer‐assisted implant surgery (sCAIS).Materials and MethodsA maxillary model without incisors was used to plan for two implants at the lateral incisor locations. According to the planned implants, sCAIS surgical template and a four‐unit interim prosthesis were designed. Four prostheses were fabricated based on the design and insertion workflow. The first prosthesis involved complete fabrication (CF) of the interim prosthesis, where the interim prosthesis is fabricated for laboratory attachment to abutments. The other three prostheses were produced by partial fabrication (PF), where the interim prosthesis shell was produced with internal spacing between the fitting surface and the abutments. The PF prostheses were cemented on abutments attached to the inserted implants. Three different PF prosthesis designs were included with different levels of internal spacing: 100 μm (PF.1), 200 μm (PF.2), and 300 μm (PF.3). A total of 15 surgical models received implants on which each prosthesis was seated and scanned by a laboratory scanner. The vertical, horizontal, and proximal contact errors were measured.ResultsAlthough all prostheses were seated on every model, the CF prostheses had greater vertical error, followed by PF.1, PF.2, and PF.3 prostheses, respectively. A similar pattern was observed for proximal contact error, where PF.3 was most superior. PF.3 prostheses had the least horizontal error than the other prostheses.ConclusionsAll interim prostheses experienced errors at the vertical, horizontal, and proximal surfaces, which can be attributed to deviations of the inserted implants. The PF of interim prosthesis with increased internal spacing for intraoral insertion appeared to reduce seating errors.

Funder

International Team for Implantology

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3