Evaluating the geometric and dosimetric impact of applying anisotropic CTV to PTV margins in image‐guided post‐prostatectomy radiation therapy

Author:

Grierson Emma1,Wilkinson Dean12ORCID,Causer Lauren1ORCID,de Leon Jeremiah1ORCID

Affiliation:

1. Illawarra Cancer Care Centre Wollongong New South Wales Australia

2. Centre for Medical Radiation Physics University of Wollongong Wollongong New South Wales Australia

Abstract

AbstractIntroductionGuidelines for clinical target volume (CTV) to planning target volume (PTV) margins in post‐prostatectomy radiation therapy (PPRT) are varied and often not clearly defined. Assessment of appropriateness of margins is commonly measured on prevalence of geographic miss.MethodsCone‐beam CT (CBCT) images (n = 92) for 10 PPRT patients were incorporated to provide on‐treatment information on the appropriateness of six different CTV expansion margins in terms of geographic miss and change in dose‐volume statistics for CTV, rectum and bladder. Uniform margins included 10 mm, 5 mm, 10 mm + 5 mm posteriorly and 5 mm + 3 mm posteriorly. In addition, two anisotropic margins were evaluated by separating the superior and inferior portions of the CTV before expansion. Treatment plans were created for each PTV retrospectively.ResultsThe frequency of geographic miss was the smallest for the large uniform expansions but resulted in the highest organ‐at‐risk (OAR) doses. Geographic miss in the smaller uniform and anisotropic PTVs was more prevalent but commonly to a small volume < 1% of CTV. When averaged over all CBCT fractions, V95% dose for all CTV margins remained > 99%. The anisotropic expansions generated smaller irradiated target volumes and consequently saw up to 7.3% reduction in bladder dose when compared with similar uniform expansion margins.ConclusionSupplementing the incidence of geographic miss with dosimetric information on target coverage and OAR doses provides more informed assessment of the appropriateness of different CTV expansion margins. Our study extends the evaluation of anisotropic margins for PPRT.

Publisher

Wiley

Subject

Radiology, Nuclear Medicine and imaging,Oncology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3