Infrared flashing light through the cricothyroid membrane as guidance to awake intubation with a flexible bronchoscope: A randomised cross‐over study

Author:

Kristensen Michael S.1ORCID,Hesselfeldt Rasmus1,Brinkenfeldt Henning K.1,Biro Peter2

Affiliation:

1. Department of Anaesthesiology, Centre of Head and Orthopaedics, Rigshospitalet Copenhagen University Hospital Copenhagen Denmark

2. Faculty of Medicine Zurich University Zurich Switzerland

Abstract

AbstractBackgroundIn case of distorted airway anatomy, awake intubation with a flexible bronchoscope can be extremely difficult or even impossible. To facilitate this demanding procedure, an infrared flashing light source can be placed on the patient's neck superficial to the cricothyroid membrane. The light travels through the skin and tissue to the trachea, from where it can be registered by the advancing bronchoscope in the pharynx and seen as flashing white light on the monitor. We hypothesised that the application of this technique would allow more proximal and easier identification of the correct pathway to the trachea in patients with severe airway pathology.MethodsAs part of awake intubation, patients underwent insertion of a flexible video bronchoscope via the mouth into the trachea. The procedure was performed twice, in random order in each patient, with and without the aid of the transcutaneous flashing infrared light. All insertions were video recorded to determine at which anatomical landmark within the airway the correct pathway was identified. The videos are accessible via this link: https://airwaymanagement.dk/infrared_comparative. The predefined landmarks were in successive order: oral cavity, oro‐pharynx, tip of epiglottis, arytenoid cartilages, false cords, vocal cords and trachea, as well as the spaces between them.ResultsTwenty‐two patients had a total of 44 awake insertions with the flexible bronchoscope. The median anatomical level, at which correct identification of the trachea was obtained on the monitor, was, past the epiglottis, with the conventional technique, and at the level of the oropharynx, when using the infrared flashing light (p = .005). The time until the flashing light or the vocal cords were seen was 21 (22) S, mean (SD), and 48 (62) S, during the insertion with and without infrared flashing light activated, respectively (p = .005). Endoscopists rated it easier (p = .001) to recognise the entrance to the trachea in the infrared‐group.ConclusionDuring awake intubation of patients with airway pathology, the application of trans‐cricothyroid infrared flashing light to guide the insertion of a flexible bronchoscope significantly facilitated the recognition of the pathway into the trachea and the correct advancement of the flexible endoscope.Registration of Clinical TrialNCT03930550.

Publisher

Wiley

Subject

Anesthesiology and Pain Medicine,General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. The Infrared Red Intubation System for the management of anticipated difficult airways;European Journal of Anaesthesiology Intensive Care;2023

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3