Single energy metal artifact reduction performs better than virtual monoenergetic dual‐energy reconstruction in CT of the equine proximal phalanx

Author:

Faulkner Josephine E1ORCID,Broeckx Bart J G2,Martens Ann3,Raes Els1,Haardt Hanna3,Vanderperren Katrien1

Affiliation:

1. Department of Morphology Imaging Orthopedics Rehabilitation and Nutrition Faculty of Veterinary Medicine Ghent University Merelbeke Belgium

2. Department of Veterinary and Biosciences Faculty of Veterinary Medicine Ghent University Merelbeke Belgium

3. Department of Large Animal Surgery Anesthesia and Orthopedics Faculty of Veterinary Medicine Ghent University Ghent Belgium

Abstract

AbstractMetal artifacts in CT negatively impact the evaluation of surgical implants and the surrounding tissues. The aim of this prospective experimental study was to evaluate the ability of a single energy metal artifact reduction (SEMAR™, Canon) algorithm and virtual monoenergetic (VM) dual‐energy CT (DECT) scanning techniques to reduce metal artifacts from stainless steel screws surgically inserted into the equine proximal phalanx. Seven acquisitions of 18 cadaver limbs were performed on a Canon Aquilion One Vision CT scanner (Helical +SEMAR, Volume +SEMAR, Standard Helical, Standard Volume and VM DECT at 135, 120, and 105 keV) and reconstructed in a bone kernel. Blinded subjective evaluation performed by three observers indicated a significant effect of acquisition in both adjacent tissues (P < 0.001) and distant tissues (P < 0.001) and the best metal artifact reduction was seen with Helical +SEMAR and Volume +SEMAR. The subjective overall preference of CT acquisition type was (1) Helical +SEMAR, (2) Volume +SEMAR, (3) VM DECT 135 keV, (4) VM DECT 120 keV, (5) VM DECT 105 keV, (6) Standard Helical, (7) Standard Volume (P < 0.001). Unblinded objective evaluation performed by one observer showed that VM DECT 120 keV, Helical +SEMAR, and Volume +SEMAR performed similarly and were objectively the best at reducing blooming artifact. Overall, the best metal artifact reduction was obtained with SEMAR, followed by VM DECT. However, VM DECT performance varies with energy level and was associated with decreased image quality in distant tissues and artifactual overcorrection of metal artifacts at high energy levels.

Publisher

Wiley

Subject

General Veterinary

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3