Transmission of radiant light energy through the sides of fiber posts

Author:

Alkhallagi Turki S.1ORCID,Marghalani Thamer Y.1ORCID,Alhaddad Abdulrahman J.1,Qutub Osama A.1,Abuzinadah Samar2,Bundugji Maha H.3

Affiliation:

1. Oral and Maxillofacial Prosthodontics Department, Faculty of Dentistry King Abdulaziz University Jeddah Saudi Arabia

2. Restorative Department, Faculty of Dentistry King Abdulaziz University Jeddah Saudi Arabia

3. General Dentist and Operative Dentistry, Dental Department King Faisal Specialists Hospital and Research Center Saudi Arabia

Abstract

AbstractObjectivesResin cements are light polymerized, but the light may not reach all areas of root canals. The purpose of this study was to determine the best predictor of transmitted light radiant exposure (TLRE) from posts' sides.Materials and MethodsFiber posts were placed in a custom‐made apparatus and advanced by 1‐mm increments. The LED curing probe tip was activated for 40 s on the coronal end of the post. The TLRE was measured with an LED radiometer detector positioned on the side of the post exposed by an opening in the apparatus. Hierarchical multiple linear regression analysis was performed.ResultsPost system explained an additional 23.62% of the variation in TRLE. Adding actual post diameter explained an additional 62.64% of the variation in TRLE. While adding post length explained an additional 0.67%.Changing post system from FiberKleer to Postec Plus will decrease the mean value of TRLE by 4.90 units on average. Also, a one‐unit increase of actual post diameter and length will decrease the value of TRLE by 44.96 and 0.44 units respectively. The TLRE ranged from 46 to 290 mJ/cm2, which was between 0.73% and 6.63% of the original emanating light.ConclusionsThe changes in post system, posts' diameter and length can be used to predict the unit changes in TLRE on the side of a translucent fiber post. Emanating radiant exposure from the side of the post was lower than 6.63% of the exposure entering the post.Clinical RelevanceFiber post diameter and length and post system can influence light radiant exposure transmitted from posts' sides, transmitting minimal radiant exposure, which can be increased by increasing curing duration.

Publisher

Wiley

Subject

General Dentistry

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3