Effect of different intraoral scanners and scanbody splinting on accuracy of scanning implant‐supported full arch fixed prosthesis

Author:

Ashraf Yasmine1,Abo El Fadl Ahmad1,Hamdy Amina1,Ebeid Kamal1

Affiliation:

1. Department of Fixed Prosthodontics, Faculty of Dentistry Ain Shams University Cairo Egypt

Abstract

AbstractObjectiveThis study evaluated the accuracy of different intraoral scanners (IOS) for scanning of implant‐supported full arch fixed prosthesis with different implant angulations with and without scanbodies splinting.Materials and MethodsTwo maxillary models were designed and fabricated to receive an all‐on‐four implant retained. The models were divided into two groups according to the angulation of the posterior implant (Group 1; 30 and Group 2; 45). Each group was then divided into three subgroups according to the type of IOS used: Subgroup C; Primescan, subgroup T; Trios4, and subgroup M; Medit i600. Then each subgroup was divided into two divisions according to scanning technique; division S: splinted and division N: nonsplinted. Ten scans were made by each scanner for every division. Trueness and precision were analyzed using Geomagic controlX analysis software.ResultsAngulation had no significant effect on both the trueness (p = 0.854) and precision (p = 0.347). Splinting had a significant effect on trueness and precision (p < 0.001). Scanner type had a significant effect on trueness (p < 0.001) and precision (p < 0.001). There was no significant difference between trueness of Trios 4 (112.15 ± 12.85) and Primescan (106.75 ± 22.58). However, there was a significant difference when compared to trueness of Medit i600 (158.50 ± 27.65). For the precision results Cerec Primescan showed the highest precision (95.45 ± 33.21). There was a significant difference between the three scanners, precision of Trios4 (109.72 ± 19.24) and Medit i600 (121.21 ± 17.26).ConclusionCerec Primescan has higher trueness and precision than Trios 4 and Medit i600 in full arch implants scanning. Splinting the scanbodies improve the accuracy of full arch implants scanning.Clinical SignificanceCerec Primescan and 3Shape Trios 4 can be used for scanning of All‐on‐four implant supported prosthesis when scanbodies are splinted using a modular chain device.

Publisher

Wiley

Subject

General Dentistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3