Remote monitoring of implantable cardiac monitors in patients with unexplained syncope: Predictors of false‐positive alert episodes

Author:

Russo Vincenzo1ORCID,Covino Simona1,De Pasquale Valentina1,Parente Erika1,Comune Angelo1,Rago Anna1,Papa Andrea Antonio1,Ammendola Ernesto1,Spadaro Guerra Andrea2,Napoli Paola2,Golino Paolo1,Nigro Gerardo1

Affiliation:

1. Cardiology and Syncope Unit Department of Medical Translational Sciences University of Campania “Luigi Vanvitelli” – Monaldi Hospital Naples Italy

2. Clinical Research Unit Biotronik Italia S.p.A. Milan Italy

Abstract

AbstractBackgroundRemote monitoring is recommended for patients with implantable cardiac monitors (ICMs), but compared to other cardiac implantable devices, ICMs are less accurate and transmit a higher number of alerts.ObjectiveThe aim of this study was to investigate the predictors of false‐positive (FP) arrhythmic alerts in patients with unexplained syncope who were implanted with ICM and followed by an automatic remote monitoring system.MethodsWe retrospectively evaluated all consecutive patients who received a long‐sensing vector ICM for unexplained syncope between January 2019 to September 2021 at our Syncope Unit. The primary endpoint was the incidence of the first FP episode. The secondary endpoints included assessing the incidence of FP episodes for all types of algorhythms and indentifying the reasons for the misdetection of these episodes.ResultsAmong 105 patients (44.8% males, median age 51 years), 51 (48.6%) transmitted at least one FP alert during a median follow‐up of 301 days. The presence of pre‐ventricular complexes (PVCs) on the resting electrocardiogram was the only clinical characteristic associated with an increased risk of FP alerts (adjusted Hazard ratio [HR] 5.76 [2.66–12.4], p = 0.010). The other significant device‐related variables were a low‐frequency filter at 0.05 Hz versus the default 0.5 Hz (adjusted HR 3.82 [1.38–10.5], p = 0.010) and the R‐wave amplitude (adjusted HR 0.35 [0.13–0.99], p = 0.049).ConclusionPatients who have PVCs are at higher risk of inappropriate ICM activations. To reduce the occurrence of FP alerts, it may be beneficial to target a large R‐wave amplitude during device insertion and avoid programming a low‐frequency filter at 0.05 Hz.

Publisher

Wiley

Subject

Cardiology and Cardiovascular Medicine,General Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3