Evolution of ventricular and valve function in patients with right ventricular pacing – A randomized controlled trial comparing leadless and conventional pacing

Author:

Garweg Christophe12ORCID,Duchenne Jürgen1,Vandenberk Bert1,Mao Yankai3,Ector Joris1,Haemers Peter1,Poels Patricia2,Voigt Jens‐Uwe1,Willems Rik1

Affiliation:

1. Department of Cardiovascular Sciences University of Leuven Leuven Belgium

2. Department of Cardiology University Hospitals Leuven Leuven Belgium

3. Department of Diagnostic Ultrasound & Echocardiography Sir Run Run Shaw Hospital Zhejiang University School of Medicine Hangzhou Zhejiang China

Abstract

AbstractBackgroundLeadless pacemakers (PMs) were recently introduced to overcome lead‐related complications. They showed high safety and efficacy profiles. Prospective studies assessing long‐term safety on cardiac structures are still missing.ObjectiveThe purpose of this study was to compare the mechanical impact of Micra with conventional PM on heart function.MethodsWe conducted a non‐inferiority trial in patients with an indication for single chamber ventricular pacing. Patients were 1:1 randomized to undergo implantation of either Micra or conventional monochamber ventricular pacemaker (PM). Patients underwent echocardiography at baseline, 6 and 12 months after implantation. Analysis included left ventricular ejection fraction (LVEF), global longitudinal strain (GLS) and valve function. N‐terminal‐pro hormone B‐type natriuretic peptide (NT‐pro‐BNP) levels were measured at baseline and 12 months.ResultsFifty‐one patients (27 in Micra group and 24 in conventional group) were included. Baseline characteristics were similar for both groups. At 12 months, (1) the left ventricular function as assessed by LVEF and GLS worsened similarly in both groups (∆LVEF −10 ± 7.3% and ∆GLS +5.7 ± 6.4 in Micra group vs. −13.4 ± 9.9% and +5.2 ± 3.2 in conventional group) (p = 0.218 and 0.778, respectively), (2) the severity of tricuspid valve regurgitation was significantly lower with Micra than conventional pacing (p = 0.009) and (3) median NT‐pro‐BNP was lower in Micra group (970 pg/dL in Micra group versus 1394 pg/dL in conventional group, p = 0.041).ConclusionMicra is non inferior to conventional PMs concerning the evolution of left ventricular function at 12‐month follow‐up. Our data suggest that Micra has a comparable mechanical impact on the ventricular systolic function but resulted in less valvular dysfunction.

Publisher

Wiley

Subject

Cardiology and Cardiovascular Medicine,General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3