Fibrin clot adherence on cleaned and decontaminated titanium abutment surfaces: An in vitro study

Author:

Ulusoy Habibe Öztürk1ORCID,Ercan Esra2,Özatik Orhan3,Tunalı Mustafa2

Affiliation:

1. Department of Prosthodontics Çanakkale Onsekizmart University Çanakkale Turkey

2. Department of Periodontology Çanakkale Onsekizmart University Çanakkale Turkey

3. Department of Histology and Embryology Kütahya Health Sciences University Kütahya Turkey

Abstract

AbstractStatement of ProblemOsseointegration is now primarily established, but soft tissue integration is still susceptible to failure and problematic on implant surfaces. So, implant dentistry is increasingly focusing on improving peri‐implant soft tissue integration.PurposeThe present study aimed to evaluate the blood fibrin clot formation and adhesion on the abutment after cleaning and decontamination and determine the suitable abutment surface associated with fibrin clot attachment.Materials and MethodsForty‐two abutments (14 per group) were used in the present study: a brand‐new (BN), contaminated with biofilm (CO) and decontaminated with an enzymatic cleaner and autoclave sterilization (DEC). For a fibrin clot, 9 mL of whole human blood and abutments was centrifuged at 2700 rpm for 12 min. Clots were divided into two parts for histomorphometry and scanning electron microscopy (SEM) analysis. Twelve abutments disconnected from the clot and two not treated with blood were observed under SEM.ResultsResidual debris and biofilm were observed on the abutment surface in the CO group but not in other groups. Healthy and organized fibrin clots formed on all abutments. The fibrin extension areas are distributed uniformly in BN and DEC groups but irregularly in CO. The surface percentage of the fibrin clot extensions was 41.76% ± 6.73, 26.99% ± 6.40, and 37.83% ± 9.72 for the BN, CON, and DEC groups, respectively. The blood clot‐attached areas in the CO group were statistically lower than the other groups. No difference was observed between the BN and DEC groups.ConclusionsThis study confirmed that surface contamination could influence blood clot attachment on the abutment surfaces. Cleaning and sterilization can have a favorable effect on soft tissue healing on abutment surfaces.

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3