Trueness and fit of complete‐arch implant‐supported frameworks in new‐generation additively and subtractively manufactured polymers: An in‐vitro study

Author:

Yilmaz Burak123,Donmez Mustafa Borga14,Güven Mehmet Esad5,Jamjoom Faris Z.67,Kahveci Çiğdem8,Schimmel Martin19,Çakmak Gülce1

Affiliation:

1. Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine University of Bern Bern Switzerland

2. Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine University of Bern Bern Switzerland

3. Division of Restorative and Prosthetic Dentistry The Ohio State University College of Dentistry Columbus Ohio USA

4. Department of Prosthodontics, Faculty of Dentistry Biruni University İstanbul Turkey

5. Department of Prosthodontics, Faculty of Dentistry Necmettin Erbakan University Konya Turkey

6. Restorative and Prosthetic Dental Science Department, College of Dentistry King Saud Bin Abdulaziz University for Health Sciences Riyadh Saudi Arabia

7. King Abdullah International Medical Research Center (KAIMRC) Riyadh Saudi Arabia

8. Ordu Oral and Dental Health Center Ordu Turkey

9. External Research Associate, Division of Gerodontology and Removable Prosthodontics University Clinics of Dental Medicine, University of Geneva Geneva Switzerland

Abstract

AbstractBackgroundThere is limited knowledge on the fabrication trueness and fit of additively or subtractively manufactured complete‐arch implant‐supported frameworks in recently introduced polymers.PurposeTo evaluate the trueness and marginal fit of additively or subtractively manufactured polymer‐based complete‐arch implant‐supported frameworks, comparing with those of strength gradient zirconia frameworks.Materials and MethodsA typodont model with 4 implants (left first molar (abutment 1), left canine (abutment 2), right canine (abutment 3), and right first molar (abutment 4)) was digitized (ATOS Core 80 5MP) and an implant‐supported complete‐arch framework was designed. This design file was used to fabricate frameworks from 5 different materials: strength gradient zirconia (SM‐ZR), high impact polymer composite (SM‐CR), nanographene‐reinforced PMMA (SM‐GR), PMMA (SM‐PM), and additively manufactured temporary resin (AM) (n = 10). These frameworks were digitized and each scan file was virtually segmented into 4 regions (abutments, occlusal, overall without occlusal, and overall). The surface deviations at these regions, and linear and interimplant distance deviations were evaluated (Geomagic Control X). Marginal gaps were evaluated according to triple‐scan protocol after seating frameworks on the model with the 1‐screw test. Data were statistically analyzed (α = 0.05).ResultsSurface deviations of all regions differed among tested materials (p ≤ 0.001). AM frameworks mostly had surface deviations that were similar to or lower than those of other materials (p ≤ 0.031), except for the occlusal surface, where it mostly had higher deviations (p ≤ 0.013). Abutment 4 of SM‐CR had higher linear deviations than abutment 2 (p = 0.025), and material type did not affect the linear deviations within abutments (p ≥ 0.171). Interimplant distance deviations differed within and among materials (p ≤ 0.017), except for those between abutments 1 and 2 among materials (p = 0.387). Marginal gaps of subtractively manufactured materials differed among abutments, while those of abutments 3 and 4 differed among materials (p ≤ 0.003). AM frameworks mostly had lower marginal gaps at abutments 3 and 4 (p ≤ 0.048).ConclusionsAlthough there was no clear trend among tested materials for measured deviations, marginal gaps of additively manufactured resin were mostly lower than those of subtractively manufactured materials and did not differ among abutment sites. Nevertheless, the differences in measured deviations among materials were small and marginal gaps were within the previously reported acceptability thresholds.

Publisher

Wiley

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3