Impact of CBCT acquisition protocols and artifact reduction filters on diagnosing vertical root fractures

Author:

Hilgert Eduarda Adams1,Liedke Gabriela Salatino2ORCID,da Silveira Tiecher Priscila Fernanda1,Arus Nádia Assein1,de Oliveira Gamba Thiago1ORCID,da Silveira Heraldo Luis Dias1,Vizzotto Mariana Boessio1

Affiliation:

1. School of Dentistry, Surgery and Orthopedics Department Universidade Federal do Rio Grande do Sul (UFRGS) Porto Alegre Rio Grande do Sul Brazil

2. School of Dentistry, Stomatology Department Universidade Federal de Santa Maria (UFSM) Santa Maria Rio Grande do Sul Brazil

Abstract

AbstractAimTo evaluate the impact of acquisition protocols and artifact reduction filters in cone beam computed tomography on diagnosing vertical root fractures in endodontically treated teeth with and without intraradicular posts.Materials and MethodsWe analyzed 480 tomographic images acquired from two J. Morita scanners (0.125‐ and 0.08‐mm voxel sizes protocols), with application of a blooming artifact reduction filter. Three evaluators assessed these images for root fractures using a 5‐point Likert scale. Diagnostic accuracy between filters and protocols was determined using generalized linear models with binomial distribution for the outcome, considering protocol, filter, and dental status. Sensitivity, specificity, positive predictive value, and negative predictive value were also estimated for the filters and protocols.ResultsThe 0.08‐mm voxel size protocol demonstrated a significantly higher percentage of accurate diagnosis compared to the 0.125‐mm protocol (p = .001). No statistically significant differences (p ≥ .087) were observed for filter application, interaction between protocol and filter, or dental status. Accuracy, sensitivity, and specificity values were respectively: .93, .87, 1.00 (protocol 1); .99, .99, .99 (protocol 2); .98, .96, .99 (no filter); .95, .90, 1.00 (with filter).ConclusionThe new findings found for the two J Morita scanners used in our study were that images acquired using the voxel size of 0.08 mm showed an improvement in the diagnosis of root fractures and the filters in these devices have no relevance significant for the diagnosis.

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3