Soft tissue elasticity at teeth and implant sites. A novel outcome measure of the soft tissue phenotype

Author:

Tavelli Lorenzo123ORCID,Barootchi Shayan124ORCID

Affiliation:

1. Department of Oral Medicine, Infection, and Immunity, Division of Periodontology Harvard School of Dental Medicine Boston Massachusetts USA

2. Center for Clinical Research and Evidence Synthesis in Oral Tissue Regeneration (CRITERION) Boston Massachusetts USA

3. School of Dentistry Universidad Catolica de Santiago de Guayaquil (UCSG) Guayaquil Ecuador

4. Department of Periodontics & Oral Medicine University of Michigan School of Dentistry Ann Arbor Michigan USA

Abstract

AbstractAimTo assess ultrasonographic tissue elasticity at teeth and implant sites and its variation after peri‐implant soft tissue augmentation with a connective tissue graft (CTG).MethodsTwenty‐eight patients, each contributing with one clinically healthy dental implant exhibiting a soft tissue dehiscence (PSTD), were included. Implant sites were augmented with CTG and monitored over 12 months. Ultrasonographic strain elastography, expressed as strain ratios (SR1, SR2, and SR3, respectively) was assessed at baseline, 6‐, and 12‐month, and compared with the corresponding contralateral homologous natural tooth. SR1 assessed the strain/elasticity of the midfacial coronal portion of the soft tissue in comparison to the natural tooth crown/implant‐supported crown, SR2 evaluated the strain of the midfacial coronal soft tissue in relation to the one of the alveolar mucosa, while SR3 depicted the strain of the midfacial soft tissue in relation to the interproximal soft tissue on the transverse ultrasound scan.ResultsSR1 in natural dentition and at implant sites was 0.20 ± 0.08 and 0.30 ± 0.14, respectively (p = .002), indicating that the coronal portion of the soft tissue around teeth is generally more elastic than its counterpart around dental implants. Soft tissue augmentation with CTG promoted an increased stiffness of the midfacial coronal portion of the soft tissue over 12 months (p < .001 for SR1, SR2, and SR3). Strain ratios at the 12‐month time points were significantly higher than the values observed at 6 months (p < .001). Regression analysis demonstrated that strain elastography ratios in natural dentition were significantly associated with keratinized gingiva width, and gingival thickness. At implant sites, SR1 was significantly associated with keratinized mucosa width and mucosal thickness (p < .001 for both correlations), SR2 was significantly associated with keratinized mucosa width (p = .013), and SR3 was significantly associated with the surgical technique performed in combination with CTG (p = .022).ConclusionUltrasound strain elastography captures and quantifies tissue elasticity and its changes after soft tissue augmentation. A different baseline tissue elasticity was observed between teeth and dental implants in the most coronal aspect of the soft tissue. The main factors affecting tissue elasticity‐related outcomes were the keratinized tissue width, and mucosal thickness.

Funder

Delta Dental Foundation

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3