Abstract
Pluronic F-127 (PF-127) hydrogel is a versatile biomaterial with promising applications in drug delivery, tissue engineering, and regenerative medicine. PF-127 has antiadhesive activity that prevents bacterial adhesion by creating a hydrated layer on the bacterial surface. This property makes PF-127 suitable for preventing implant-associated infections. In this study, we aimed to evaluate the antibacterial properties of PF-127 using field isolates of Staphylococcus aureus (Gram-positive bacteria) and Escherichia coli (Gram-negative bacteria) and compare them with different antibiotic standards. The antimicrobial potential was assessed using disk diffusion assays with four standard concentrations (20%, 25%, 30%, and 40%). The test microorganisms were inoculated on agar plates, and sterile filter paper disks infused with PF-127 hydrogels were placed alongside standard antibiotic disks. After incubation, the inhibition zones were measured to determine antimicrobial activity. Our results showed that PF-127 lacked intrinsic antimicrobial activity against S. aureus and E. coli at the tested concentrations. In conclusion, PF-127 hydrogel is a promising neutral carrier hydrogel system for loading antibiotics and antimicrobial compounds. Its unique properties, such as biocompatibility and thermo-responsive behaviour, combined with its antiadhesive activity, make it an ideal candidate for various biomedical applications.
Publisher
Journal of Pure and Applied Microbiology
Subject
Applied Microbiology and Biotechnology,Microbiology,Biotechnology
Reference28 articles.
1. 1. Escobar-Chavez JJ, Lopez-Cervantes M, Naik A, Kalia YN, Quintanar-Guerrero D, Ganem-Quintanar A. Applications of thermo-reversible pluronic F-127 gels in pharmaceutical formulations. J Pharm Pharm Sci. 2006;9(3):339-358.
2. 2. Almeida H, Amaral MH, Lobao P, Lobo JM. Pluronic® F-127 and Pluronic Lecithin Organogel (PLO): main features and their applications in topical and transdermal administration of drugs. J Pharm Pharm Sci. 2012;15(4):592-605. doi: 10.18433/j3hw2b.
3. 3. Brunet-Maheu JM, Fernandes JC, de Lacerda CA, Shi Q, Benderdour M, Lavigne P. Pluronic F-127 as a cell carrier for bone tissue engineering. J Biomater Appl. 2009;24(3):275-87. doi: 10.1177/0885328208096534.
4. 4. Dumortier G, Grossiord JL, Agnely F, Chaumeil JC. A review of poloxamer 407 pharmaceutical and pharmacological characteristics. Pharm Res. 2006;23(12):2709-2728. doi: 10.1007/s11095-006-9104-4
5. 5. Yang HC, Chang HY. Novel air leak test using surfactant for lung surgery. J Thorac Dis. 2018;10(12):6472-6474. doi: 10.21037/jtd.2018.11.34
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献