Abstract
An analytical expression was developed to define the incipient drawdown of a thermocline into a submerged intake equipped with a circular cover. The critical discharge at the incipient drawdown was expressed in terms of dimensionless variables defining the thermal structure of the surrounding water body and the geometric properties of the intake structure.The relationship was verified by laboratory experiments and by field data.
Publisher
Canadian Science Publishing
Subject
General Environmental Science,Civil and Structural Engineering
Cited by
6 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献