Accuracy of aggregate 2- and 3-component models of body composition relative to 4-component for the measurement of changes in fat mass during weight loss in overweight and obese subjects

Author:

Lara Jose1,Johnstone Alexandra M.2,Wells Jonathan3,Jebb Susan4,Siervo Mario1

Affiliation:

1. Human Nutrition Research Centre, Institute for Ageing and Health, Newcastle University, Campus for Ageing and Vitality, Newcastle on Tyne NE4 5PL, UK.

2. University of Aberdeen Rowett Institute of Nutrition and Health, Greenburn Road, Bucksburn, Aberdeen AB21 9SB, UK.

3. Childhood Nutrition Research Centre, UCL Institute of Child Health, 30 Guilford Street London WC1N 1EH, UK.

4. MRC Human Nutrition Research, Elsie Widdowson Laboratory, Fulbourn Rd., Cambridge CB1 9NL, UK.

Abstract

The 4-component (4-C) model is the reference method to measure fat mass (FM). Simpler 2-component (2-C) models are widely used to assess FM. We hypothesised that an aggregate 2-C model may improve accuracy of FM assessment during weight loss (WL). One hundred and six overweight and obese men and women were enrolled in different WL programs (fasting, very low energy diet, low energy diet). Body density, bone mineral content, and total body water were measured. FM was calculated using 2-C, 3-C, and 4-C models. Aggregate equations for 2-C, 3-C, and 4-C models were calculated, with the aggregate 4-C model assumed as the reference method. The aggregate approach postulates that the average of the individual estimates obtained from each model is more accurate than the best single measurement. The average WL was −7.5 kg. The agreement between 3-C and 4-C models for FM change was excellent (R2= 0.99). The aggregate 2-C equation was more accurate than individual 2-C estimates in measuring changes in FM. The aggregate model was characterised by a lower measurement error at baseline and post-WL. The relationship between the aggregate 3-C and 4-C component models was highly linear (R2= 0.99), whereas a lower linearity was found for the aggregate 2-C and 4-C model (R2= 0.72). The aggregate 2-C model is characterised by a greater accuracy than commonly applied 2-C equations for the measurement of FM during WL in overweight and obese men and women.

Publisher

Canadian Science Publishing

Subject

Physiology (medical),Nutrition and Dietetics,Physiology,General Medicine,Endocrinology, Diabetes and Metabolism

Reference39 articles.

1. Body composition in elderly people: effect of criterion estimates on predictive equations

2. Behnke, A.R. 1961. Comment on the determination of whole body density and a resume of body composition data. Washington, DC: National Academy of Sciences NRC.

3. Behnke, A.R., and Wilmore, J.H. 1974. Evaluation and regulation of body build and composition. Englewood Cliffs; London: Prentice-Hall.

4. Comparing methods of measurement: why plotting difference against standard method is misleading

5. STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3