Author:
Bisby L A,Kodur V KR,Green M F
Abstract
Confinement of reinforced concrete columns by circumferential fibre reinforced polymer (FRP) wraps is a promising application of FRP materials for structural strengthening and seismic upgrading of deteriorated or under-strength members. However, if this technique is to be used in buildings, parking garages, and industrial structures, then the ability of FRP materials and FRP-wrapped columns to withstand the effects of fire must be demonstrated and evaluated. This paper presents the results of parametric studies conducted using a previously presented and partially validated numerical fire simulation model to investigate the effects of a number of parameters on the fire behaviour of FRP-wrapped reinforced concrete columns. It is demonstrated that appropriately designed and adequately protected FRP-wrapped reinforced concrete columns are capable of achieving fire endurances equivalent to conventionally reinforced concrete columns. Furthermore, this study also suggests that a holistic approach to the fire design of FRP-wrapped members is required, rather than an approach based on the specific performance of the FRP materials. Design recommendations for the fire-safe design of FRP-wrapped concrete columns are presented and discussed.Key words: reinforced concrete, rehabilitation, strengthening, fibre reinforced polymer, fire endurance, fire insulation, numerical modelling.
Publisher
Canadian Science Publishing
Subject
General Environmental Science,Civil and Structural Engineering
Cited by
16 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献