Author:
Al-Hunaidi M O,Chen P A,Rainer J H,Tremblay M
Abstract
The resonant-column test method was used in this study to determine the dynamic shear moduli and damping ratios of frozen and unfrozen soil samples. Naturally frozen soil specimens were obtained in-situ during the winter. A series of tests were carried out on the frozen soil specimens in a cold room at 9°C. The same specimens, after allowing them to thaw, were then tested at room temperature. Test results show that at low-amplitude shear stains the damping ratio of frozen soil specimens is roughly twice that of unfrozen samples. In addition, the dynamic shear modulus for soil specimens while frozen is significantly greater (30 or 50 times) than that of unfrozen specimens. These results provide a basis for explaining an observation that bus-induced vibrations in buildings while the top soil is frozen in winter are about one-half those induced while the soil is not frozen. Key words: resonant-column test, shear modulus, damping ratio, frozen soil, ground vibration.
Publisher
Canadian Science Publishing
Subject
Civil and Structural Engineering,Geotechnical Engineering and Engineering Geology
Cited by
43 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献