Author:
Burnotte Fabien,Lefebvre Guy,Grondin Gilles
Abstract
Electroosmotic (e.o.) consolidation of clays has been known in geotechnical engineering for many decades but is in fact seldom used. The analysis of published data from case records indicates that the power losses at the soilelectrode contact constitute a major problem for the field application of e.o. consolidation. A laboratory study, where field conditions were reproduced, has demonstrated the efficiency of a chemical treatment at the electrodes to enhance potential transfer to soil. The chemical treatment was evaluated in a large field demonstration test where over 700 m3of clay was consolidated by electroosmosis. The paper describes the site, the field setup, and the results and analysis of the monitoring during the 48 days of the e.o. treatment. The results of the post-treatment geotechnical investigation after 12% of clay compression due to electroosmotic consolidation are also presented and discussed. These results confirm that soft clay deposits can be successfully treated by e.o. consolidation, at a competitive cost compared with other alternatives, when power losses at the soilelectrode contact are controlled.Key words: case record, electroosmosis, soft clays, consolidation, soil improvement.
Publisher
Canadian Science Publishing
Subject
Civil and Structural Engineering,Geotechnical Engineering and Engineering Geology
Cited by
128 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献