THE MEASUREMENT OF ENERGIES AND INTENSITIES OF γ-RAYS WITH A PAIR SPECTROMETER

Author:

Kinsey B. B.,Bartholomew G. A.

Abstract

The performance of a pair spectrometer of the Walker and McDaniel type is discussed from both a theoretical and an experimental point of view. It is shown that the energy of the γ-ray may be measured to a first approximation by the product of the distance between the inner edges of the slits which define the coincidence counters and the highest value of the magnetic field at which coincidences are found. A more accurate value of the energy of the γ-ray may be obtained by adding a small correction, called the "toe" correction, to the result so obtained. The magnitude of this correction is dependent on the γ-ray energy and on the width of the slits and is obtained from calculations of the shape of the coincidence peak based on the Bethe–Heitler formula. The correction depends very little on the length of the slits or on the thickness of the radiator. The relation between the calculated correction and the slit width has been examined experimentally. It is shown that the ultimate accuracy in energy measurement depends on the homogeneity of the magnetic field and on the error involved in the calculated toe correction. The latter error can be minimized by using very narrow slits and may be eliminated by plotting the value of magnetic field at the upper limit of the coincidence spectrum against the slit width and extrapolating the curve so obtained to zero slit width. The uncertainty in the magnetic field of the present instrument introduces a possible systematic error of about 0.05%. Measured values of the energies of a number of neutron capture γ-rays are compared with the values derived from the energy balance in (d, p) reactions. The results are in good agreement (within 0.1%).The relative counting efficiency as a function of energy is calculated theoretically and found to be in good agreement with experiment from 2.75 to 7.4 Mev. Above 7.4 Mev. no good method of checking the theoretical efficiency has been found. The absolute value of the counting efficiency at 2.75 and 7.38 Mev. has been measured by an ionization chamber method and is found to be in rough agreement with theoretical estimates.

Publisher

Canadian Science Publishing

Subject

General Physics and Astronomy

Cited by 49 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Prompt γ-ray analysis with reactor neutrons (Review);Bunseki kagaku;2002

2. The 14N(n, γ)15N reaction as both an intensity and energy standard;Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment;1986-09

3. Magnetic pair and compton spectrometers;Nuclear Instruments and Methods;1979-06

4. Capture radiative partielle des neutrons de résonance dans l'or et le cobalt;Nuclear Physics A;1969-06

5. Spins and Widths of Energy Levels in the 5-9-MeV Region;Physical Review;1969-03-20

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3