Abstract
If three resistors, which are kept at different temperatures, are arranged in form of a π network and if two of the thermal noise voltages appearing across the π network are multiplied together and averaged with respect to time, then under certain conditions the correlation between those voltages can be made zero. This condition is used to calculate the temperature of one noise source provided all the resistance values and the other temperatures are known. A noise thermometer of this kind was constructed which is capable of measuring temperatures below approximately 140° K. The boiling points of liquid oxygen and liquid nitrogen were determined absolutely within 0.2%. Between 1.3° K and 4.2° K the thermometer had to be calibrated due to errors arising in the equipment and the measured temperatures were then accurate within ± 1%.