Field performance of four vibrating-wire piezometer installation methods

Author:

Young Nathan123,Lemieux Jean-Michel123,Mony Laura1,Germain Alexandra1,Locat Pascal4,Demers Denis4,Locat Ariane5,Locat Jacques1

Affiliation:

1. Département de géologie et de génie géologique, Université Laval, 1065 avenue de la Médecine, Québec, QC G1V 0A6, Canada.

2. Centre québécois de recherche sur l’eau, Université Laval, 1065 avenue de la Médecine, Québec, QC G1V 0A6, Canada.

3. Centre d’études nordiques, Université Laval, 2405 rue de la Terrasse, Québec, QC G1V 0A6, Canada.

4. Section des mouvements de terrain, Direction de la géotechnique et de la géologie, Ministère des Transports du Québec, Québec, QC, Canada.

5. Département de génie civil et des eaux, Université Laval, 1065 avenue de la Médecine, Québec, QC G1V 0A6, Canada.

Abstract

Vibrating-wire piezometers provide a number of advantages over the traditional hydraulic piezometer design. There are currently many methods and configurations for installing vibrating-wire piezometers, the most common being: single piezometers in sand packs (SP), multilevel piezometers in sand packs (MLSP), and fully grouted multilevel piezometers using either bentonite (FGB) or cement−bentonite grout (FGCB). This study assesses the performance of these four different installation methods at a field site possessing complex stratigraphy, including glacial and marine sediments. To accomplish this objective, pore pressure data recorded between December 2017 and July 2019 were analyzed. Data indicate that SP, MLSP, and FGB piezometers performed most reliably, because piezometers installed at the same depth with these methods recorded similar pressure variations that were coherent with the hydrogeological setting. Of the two fully grouted installations using cement−bentonite grout, one installation failed completely due to a hydraulic short circuit, likely caused by preferential flow occurring along the wires of the embedded instruments. The lack of a standard method for mixing cement−bentonite grout at the time of construction likely contributed to the failure of the FGCB installations, as the grout mixture used in this study was likely too viscous to provide a suitable seal.

Publisher

Canadian Science Publishing

Subject

Civil and Structural Engineering,Geotechnical Engineering and Engineering Geology

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3