Affiliation:
1. Recep Tayyip Erdogan University, Faculty of Arts & Sciences, Department of Chemistry, Rize 53100, Turkey.
Abstract
A Pt electrode modified by polyaniline–poly(3-methylthiophene)–poly(3,3′-diaminobenzidine) was used for amperometric determination of epinephrine in a solution of NaHSO4/Na2SO4 (pH 2.0). For these studies, potentials between 0.40 and 0.50 V were applied, and the best response was obtained at 0.45 V. The limit of detection, limit of quantification, and the linear dynamic range were 1.23 × 10−4, 4.10 × 10−4, and 4.10 × 10−4 to 100.0 mmol L−1, respectively. These results were compared with determinations using Pt electrodes that were coated and uncoated with homopolymers. To check the accuracy of the developed method and the matrices interference, determination of epinephrine was performed in human serum samples using this modified electrode. The epinephrine concentrations were adjusted to 1.0 and 5.0 mmol L−1, and recovery values were calculated as 100.4% and 96.8%, respectively. It is significant that the determination of epinephrine was carried out at a lower potential (0.45 V) than the oxidation potential of epinephrine (0.65 V) without any matrix effect.
Publisher
Canadian Science Publishing
Subject
Organic Chemistry,General Chemistry,Catalysis
Cited by
3 articles.
订阅此论文施引文献