Abstract
Because of the difficulties in applying current earthquake requirements in the National Building Code of Canada to existing buildings, a document "Guidelines for the seismic evaluation of existing buildings" has been developed to provide alternative criteria. The Guidelines are based primarily on similar U.S. documents with changes to suit Canadian seismicity and practice. The basis of the document is earthquake damage experience as it relates to life safety, and the methodology is based on the identification of deficiencies of the building from a master list known from earthquake experience to result in life-threatening failures. Potential deficiencies are checked against evaluation criteria which are based on the NBC/CSA seismic limit states design using a load reduction factor of 0.6. The paper provides a background on those features which differ substantially from the NBC requirements. Key words: existing buildings, seismic evaluation, procedure, criteria.
Publisher
Canadian Science Publishing
Subject
General Environmental Science,Civil and Structural Engineering
Cited by
8 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献