Author:
Rowe R Kerry,Sangam Henri P,Lake Craig B
Abstract
A geomembrane compacted clay composite liner system used to contain municipal solid waste (MSW) landfill leachate for 14 years is evaluated. Field observations of the geomembrane revealed many defects, including holes, patches, and cracks. Physical, chemical, and mechanical tests conducted on samples collected from five different locations of the liner suggest that samples continuously exposed to sunlight and high temperatures experienced more degradation compared to samples that were covered by leachate or soil. Sorption and diffusion tests revealed that the permeation coefficients of volatile organic compounds were in the range of 4 × 1012 to 6 × 1011 m2/s and that, with respect to these parameters, there was no significant difference between samples with different exposure levels. However, the permeation coefficients were between four and five times lower than values obtained for unaged HDPE geomembranes typical of present day production. Contaminant modelling of the entire lagoon liner suggests that the geomembrane liner most likely stopped being effective as a contaminant barrier to ionic species sometime between 0 and 4 years after the installation.Key words: liquid containment, composite liner, diffusion, HDPE geomembrane, performance.
Publisher
Canadian Science Publishing
Subject
Civil and Structural Engineering,Geotechnical Engineering and Engineering Geology
Cited by
64 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献