Author:
Hatton C. J.,Carimichael H.
Abstract
A comprehensive experimental study has been made of the NM-64 neutron monitor. The counting rate has been measured as a function of the thickness of the reflector, of the separation of the counters, of the thickness of the inner moderator, and of the gas pressure in the counters. It is shown that the figures given in the internationally approved specification represent a satisfactory optimization of the design. The counting rate of the NM-64 monitor is found to be 3.3 times that of an IGY monitor of the same horizontal area. The origin and movement of both fast and thermal neutrons within the monitor have been investigated using cadmium sheets and by studying events producing counts in more than one counter.
Publisher
Canadian Science Publishing
Subject
General Physics and Astronomy
Cited by
124 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献