Nonhomogeneous force application during typical flutter ablation explains local difficulties in lesion creation

Author:

Latcu Decebal Gabriel1ORCID,Enache Bogdan1ORCID,Benhenda Nazih1,Cozma Dragos2,Casado-Arroyo Ruben3ORCID,Anselme Frédéric4ORCID,Pathak Atul1ORCID,Saoudi Nadir1

Affiliation:

1. Centre Hospitalier Princesse Grace, Monaco, France

2. „Victor Babes” University of Medicine and Pharmacy, Timisoara, Romania

3. Department of Cardiology, Erasme Hospital, Université Libre de Bruxelles, Belgium

4. Department of Cardiology, Rouen University Hospital, Rouen, France

Abstract

Introduction – The current scientific literature suggests similar or even better catheter contact on caval regions of the cavo-tricuspid isthmus (CTI) compared to the more medial or annular part. Yet CTI ablation can be challenging owing to instability at the inferior vena cava (IVC) edge. No study specifically addressed the issue of catheter-tissue contact on caval/mid/annular regions of the CTI. Methods – Twenty-seven patients (22 men, 67±12 years) underwent typical atrial flutter ablation with a contact force (CF) sensing catheter (Tacticath 75, Abott) and were prospectively included. Operators aimed at optimizing CF for all RF pulses. The product of CF, time (force-time integral; FTI) and delivered power (FTPI) has been proposed as an estimate of lesion size. In a subset of 8 consecutive pts, electrograms (EGM) of all RF lesions were analyzed. Annular CTI was defined as sites showing both atrial and ventricular near-field bipolar EGM. Mid CTI sites had only atrial near field bipolar EGM on both distal and proximal dipoles (or distal only in case of superior-to-inferior approach). Caval sites had near-field bipolar EGM only in distal dipole, while the proximal one was inferiorly located. Results – Complete persistent (at 30 min) CTI block was obtained in all patients. A steerable sheath was used in 12 pts (44%). Procedure duration was 93±30 min, RF delivery time 10±6 min, fluoroscopy time 14±8 min. Mean CF was 15.8±5.9 g. CF was significantly lower (11.1±9.7 g) at the caval CTI than at mid CTI (19.9±11.8 g) and annular CTI (20±12.2 g; p=0.001). CF and FTI were higher during sinus rhythm than during Fl (23.2±15.3 vs 18.5±15.4 g, p=0.04 and 677±432 vs 532±357 gs, p=0.03). Use of a sheath improved mean CF (24.4±12.5 vs 18.4±14.9 g, p=0.01) but this was not significant at caval sites (17.5±11.4 vs 12.6±10.7 g, p=0.31). Conclusion – Applied forces are significantly lower at the IVC edge during CTI ablation. This supports the use of a steerable sheath in challenging cases.

Publisher

Societatea Romana de Cardiologie

Subject

Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3