A New Look at the Minimum Miscibility Pressure (MMP) Determination from Slimtube Measurements

Author:

Amao Abiodun Matthew1,Siddiqui Shameem1,Menouar Habib1,Herd Bob L.1

Affiliation:

1. Department of Petroleum Engineering, Texas Tech University

Abstract

Abstract Slimtube measurement is one of the standard experimental techniques used for determining the minimum miscibility pressure (MMP) of an oil and injection gas system prior to the initiation of an enhanced oil recovery (EOR) project. It is preferred because it involves actual fluid displacement in a porous medium. However, the specific criterion for determining the cut-off point during the measurement is not uniquely agreed upon in the literature. Different criteria have been proposed by researchers and this has been one of the setbacks of using Slimtube measurements. The most commonly used criterion is the 1.2 PV criterion, which uses the recovery after injecting 1.2 pore volumes of the displacing gas as the cut-off. However, experimental observations show that even at supercritical condition, the volume of a gas is a strong function of the experimental pressure. Therefore, there is a need to develop an alternative means of determining the MMP that is not subject to particular pore volumes injected during Slimtube measurements. This work presents different means of determining the MMP, based entirely on recovery and the particular displacement phenomenon. In this approach, two new parameters are defined - the instantaneous recovery rate (IRR) and the oil recovery rate (ORR). The maximum values for these parameters for each experiment are used as the cut-off value. This new criteria was used in analyzing nine experimental data using oil from the Permian Basin. The results were compared with MMP prediction based on maximum recovery from each of the runs and the results were found to be in agreement. These new criteria will provide consistent cut-off point for experimental runs because Slimtube measurements take a long time to complete. The new procedure ensures that adequate data have been gathered during each experimental run, sufficient for a consistent experimental analysis.

Publisher

SPE

Cited by 17 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3