Viiscosity of Gas-saturated Bitumen

Author:

Jacobs F.A.1,Donnelly J.K.1,Stanislav J.1

Affiliation:

1. University of Calgary

Abstract

Abstract The objective of this work was to measure the effect of dissolved carbon dioxide, methane and nitrogen on the viscosity of Athabasca bitumen. To accomplish these measurements, an apparatus was designed and built. The experimental results of gas-saturated bitumen show that carbon dioxide dramatically reduces the viscosity of bitumen particularly at low temperatures. The viscosity reduces with increasing pressure and temperature. The effect of pressure on lowering the viscosity is less prominent beyond a temperature of about 100 °C. The effect of dissolved methane on the viscosity is less dramatic but still significant. Dissolved nitrogen produced a negligible change in Viscosity. Introduction The viscosity of bitumen is a physical property, the knowledge of which is essential to solving the problems associated with the development of in-situ recovery of oil from oil sands deposits. The movement of high-viscosity crude would require extremely high and impractical pressure gradients. A viscosity reduction step is thus essential in transporting the bitumen. It has been well established that at reservoir pressures. dissolved gases have a substantial effect on the viscosity of crude oil. The most complete body of data on the effect of dissolved gases on the viscosity of crude oils is contained in the work published by Simon and Graue(1). However, their work was limited to crude oils with specific gravities of less than 0.95. For Athabasca bitumen with specific gravity greater than 1.00. the only substantial volume of data that has been published is that of Ward and Clark(2). Recently. Dealy(3) reported additional data on the rheological properties of bitumen. However, no data have been reported on the effect of dissolved gases on the viscosity of oil sand bitumen. Hence, the objective of this work was to measure the effect of dissolved nitrogen, carbon dioxide and methane on the viscosity of Athabasca bitumen. To accomplish this objective, an apparatus was designed and built to saturate the bitumen with gas and measure the resultant viscosity. Experimental Apparatus A schematic flow diagram of the apparatus is shown in Figure 1. The pump draws the bitumen along with its dissolved gas from the base of the mixing cell. The liquid is then pumped through a recycle line and a circulation line. The recycle line is used to supply bitumen to the top of the mixing cell, where a large surface area is provided for gas-liquid contact. The circulation line passes through the densitometer and the viscometer before returning to the-mixing cell. The division of flow in the two lines is controlled by means of the valve in the circulation line. The entire apparatus is placed in an electrically heated air bath to achieve a uniform temperature. A Contraves Model DC 44 viscometer, consisting of a torque meter and a driving motor, which was magnetically coupled to the measuring bob inside the flow-through cup, was used for viscosity measurements. The measuring cup was modified to reduce the hold-up volume of the viscometer. The viscometer calibration curves were supplied by the manufacturer.

Publisher

Society of Petroleum Engineers (SPE)

Subject

Energy Engineering and Power Technology,Fuel Technology,General Chemical Engineering

Cited by 43 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3