A new device for the aspiration of follicular fluid for acid-base balance analysis in cattle

Author:

Cech S.,Dolezel R.,Holickova K.,Indrova E.,Kochova T.,Lopatarova M.,Mala J.,Pechova A.,Zavadilova M.,Zilka L.

Abstract

The aim of this study was to evaluate a new device for the ultrasound-guided transvaginal aspiration of follicular fluid for acid-base balance analysis (ABB set) in comparison with the original modified commercial OPU set. In the ABB set, an aspiration syringe was placed in the front part of the new tool&rsquo;s handle, next to the transducer, so as to enable direct collection of the sample into the syringe. To obtain a sufficient amount of testable fluid, reservoirs of urine (rubber balloons) were used for later aspiration under laboratory conditions in Experiment 1. Fifteen triads of samples (each triad with two punctures) were collected. While the first sample of each triad was taken using the ABB set (ABB sample), two samples were taken by one puncture using the original modified commercial OPU set: aerobic phase of sampling (AE sample) with air present in the tubing at the start of sampling and the subsequent anaerobic phase of sampling (AN sample). Values determined in the second sample from the triad (AE) varied from the values in both ABB and AN samples (pH 7.685 vs. 7.704 vs. 7.692, pCO<sub>2</sub> 11.13 vs. 10.3 vs. 10.85, pO<sub>2</sub> 6.87 vs. 8.67 vs. 7.02). In Experiment 2, ultrasound-guided transvaginal aspirations were carried out in 13 cows bearing ovarian cysts with diameters of at least 3 cm, using plastic aspiration syringes (Experiment 2P) and in 12 cows using glass aspiration syringes (Experiment 2G). The sequence of samples was the same as in Experiment 1. We found a significantly higher pH in AE in comparison to AN (7.357 vs. 7.348), lower pCO<sub>2</sub> (6.85) and higher O<sub>2</sub> (14.12) in samples of AE in comparison to samples of ABB and AN (pCO<sub>2</sub> 7.36, 7.30; O<sub>2</sub> 9.95, 10.63 respectively) in cystic fluid in Experiment 2P. We found a significantly higher pH (7.4), lower pCO<sub>2</sub> (5.98) and a higher pO<sub>2</sub> (12.35) in AE samples in comparison to ABB and AN samples of cystic fluid (pH 7.386, 7.385; pCO<sub>2</sub> 6.39, 6.35 and O<sub>2</sub> 10.56, 10.65, respectively) from Experiment 2G. We conclude that the acid-base balance assay was affected by air, present in the tubing during aerobic sampling in comparison to anaerobic and ABB set sampling. These pre-analytical changes can be prevented by the use of the ABB set because the results obtained with the ABB set were not different from that of the AN samples. We also confirmed pre-analytical changes in acid-base balance parameters in the cystic fluid after it had been stored in plastic aspiration syringes. Our new ABB set equipped with a glass aspiration syringe is suitable for sampling follicular fluid for both acid-base balance and gas analysis.

Publisher

Czech Academy of Agricultural Sciences

Subject

General Veterinary

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3