Examination of the minimum inhibitory concentration of amoxicillin and marbofloxacin against Streptococcus suis using standardised methods

Author:

Sperling D,Karembe H,Zouharova M,Nedbalcova K

Abstract

The results of the antimicrobial susceptibility testing of clinical isolates Streptococcus suis to amoxicillin and marbofloxacin obtained by the agar dilution method and broth microdilution method with the results obtained by the commercially available E-test were compared. Comparisons between the methods based on the determination of the minimal inhibitory concentration (MIC) of the antimicrobials were assessed based on the degree and frequency of the categorical agreement (Agar dilution method as a reference system) and the percentage of the categorical agreement and error rate. A statistical evaluation was determined using the Bland-Atman method. The presented MIC values, determined for the isolates in the E-test, were slightly different from the MIC values determined by the dilution tests, mainly due to the different defined testing concentrations. For the E-test as the test system and agar-dilution method as the reference system, no error of any class was detected (very major, major and minor error) and a complete categorical agreement was obtained between the evaluated methods for amoxicillin. For amoxicillin, the regression and correlation analysis show linear relationships between the E-test and the two dilution methods with significant coefficients of determination (0.62 and 0.75). The slopes of the equality and regression lines were not significantly different. However, the E-test tends to slightly overestimate the MIC values when compared to the microdilution. The reverse is true when compared with the agar dilution. There was good agreement between the E-test and the dilution methods with a low bias (0.001 3 and −0.005 0), all the experimental data were within the computed limits of agreement. For marbofloxacin, the same trends were observed with lower coefficients of determination (0.42 and 0.73) and a less favourable agreement. The E-test constantly underestimated the MIC values when compared to the two dilution methods. No significant difference between the microdilution and agar dilution was obtained.

Publisher

Czech Academy of Agricultural Sciences

Subject

General Veterinary

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3