Affiliation:
1. National Research Moscow State University of Civil Engineering
Abstract
The arrangement of heat supply of residential buildings with independent connection to external heating networks is considered, which ensures the reliability of heat supply and the necessary comfort in the premises in cold weather conditions after the official termination of the heating season or before it begins due to the supply of water from the return main of the heating network after the DHW heat exchangers. A mathematical model describing the non-stationary modes of operation of heaters of the heating system under the conditions of the implementation of this arrangement is constructed and studied. Calculations were carried out using this model, including numerical simulation on a computer using the Monte Carlo method. It is established that in this case, due to fluctuations in the waste water consumption following the daily variation in water consumption at the DHW, there occurs a decrease in the average heat transfer coefficient of the heater of the heating system and its temperature efficiency due to the fact that these values depend on the flow rate in a non-linear way, and their growth during the period of increased water intake at the DHW does not compensate for the decrease during the reduction of water consumption. It is noted that in this case, the reduction of the heat transfer coefficient lies within the usual error of engineering calculation, and this effect can be neglected. It is proved that, with a small number of heat transfer units in the heater of the heating system attributed to the heated flow, the total amount of heat transferred can decrease quite significantly (by up to 30 percent); however, with a rational choice of the heater size, such a decrease is within the limits allowed by the margins applied when setting the flow rate of delivery water and determining the heat transfer area.
Reference12 articles.
1. Tretyakova P. A., Menshikova A. A., Tretyakova T. V. Performance indicators for the use of heat pumps in a district heating system. Energy saving and water treatment 2020; 2(124); 17 – 21. (In Russ.)
2. Energy saving technologies for office buildings. R. A. Amerkhanov, L. A. Daybova, N. S. Arakelyan, E. G. Armaganyan, V. V. Dvornyi. Energy saving and water treatment 2019; 1(117): 3 – 5. (In Russ.)
3. A review of performance of zero energy buildings and energy efficiency solutions. L. Belussi, B. Barozzi, A. Bellazzi, L. Danza, A. Devitofrancesco, M. Ghellere, G. Guazzi, I. Meroni, F. Salamone, F. Scamoni, C. Scrosati, C. Fanciulli. Journal of Building Engineering 2019; 25; 100772.
4. Safiullin R. G., Akhmerova G. M. Experimental study of the thermal characteristics of a plate heat exchanger on the example of the installation "block heat point" of the center "Systems" in the KSASU. Proceedings of the VIII International Science and Technical Conference «Theoretical foundations of heat and gas supply and ventilation». – Moscow: NR MSUCE 2020; 127 – 132. (In Russ.)
5. Rafalskaya T. A. Simulation of thermal characteristics of heat supply systems in variable operating. Journal of Physics: Conference Series. XXXV Siberian Thermophysical Seminar, STS 2019 2019; 012140.
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献