Energy, exergy and entropy analysis with R1234yf as an alternate refrigerant to R134a of automobile air conditioning system

Author:

PATEL Bhaveshkumar1ORCID,PAREKH Ashok2ORCID

Affiliation:

1. Department of Mechanical Engineering, Government Engineering College Valsad, Gujarat Technological University, Gujarat, 382424, India

2. Department of Mechanical Engineering, Sardar Vallabhbhai National Institute of Technology, Surat, Gujarat, 395007 India

Abstract

A major portion of the worldwide emissions arise from mobile air-conditioning systems with hydrofluorocarbon refrigerant as working substance and which is one of major cause for the greenhouse effect. R134a refrigerant having GWP of 1400 has been extensively used in car air conditioning. To reduce greenhouse gas emissions, the current R134a refrigerant must be phase out as per Kigali Amendment. The present study deals with cooling load calculation of car model by heat balance method as per ASHRAE standard using local climate condition. Further, thermodynamic analysis of R1234yf as an alternate refrigerant to R134a has been carried out for automobile air conditioning system. The required properties of refrigerants are extracted from Engineering Equation Software. The thermodynamic analysis is carried out to study the effect of operating parameters viz. condensing temperature, evaporating tempera-ture, degree of superheating and degree of subcooling on COP, EDR, exergy efficiency and entropy generation. The previous literature reports mainly focus on separate study of either cooling load calculation or energy analysis or exergy analysis of R1234yf and R134a for au-tomobile air conditioning system, while this paper presents the comprehensive study of new low GWP R1234yf as an alternate refrigerant to R134a in automobile air conditioning system with cooling load calculation including the concept of energy, entropy and exergy analysis. The percentage difference in COP between R134a and R1234yf system varies from 2.44 % to 4.78 % while percentage difference in EDR varies from 6.79 % to 2.87 % when evaporating temperature varied from -10 °C to 10 °C. With 12 °C of superheating at compressor inlet, the COP of R134a is 3.9 whereas COP of R1234yf is 3.75, which makes 3.85 % lower than that of R134a. The R1234yf has 4.78 % lower value of exergy efficiency as compared to that of R134a at evaporating temperature of -10 °C and it is found that maximum exergy destruction takes place in compressor.

Publisher

Kare Publishing

Reference41 articles.

1. REFERENCES

2. [1] UNEP Technical Options Committee. 2018 Report of the Refrigeration, Air Conditioning and Heat Pumps Technical Options Committee. 2019. [Online]. Available: https://ozone.unep.org/sites/default/files/2019-04/RTOC-assessment-report-2018_0.pdf

3. [2] United Nations, Treaty Collection. Kigali Amendment. 2016;2:1–16.

4. [3] India Cooling Action Plan. Ozone Cell Ministry of Environment, Forest & Climate Change Government of India March. 2019.

5. [4] Yang CY, Nalbandian H. Condensation heat transfer and pressure drop of refrigerants HFO-1234yf and HFC-134a in small circular tube. Int J Heat Mass Transf 2018 Dec;127:218–227. [CrossRef]

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3