Affiliation:
1. Kuban State Medical University
2. Belarusian State Medical University
Abstract
The article discusses the evaluation of the effectiveness of the influence of thermal vibration effects on the bending strength and surface hardness of composite filling materials.The study was conducted on the basis of the Department of Therapeutic Dentistry of the Kuban State Medical University, as well as at the Krasnodar Instrument Plant “Cascade”. The samples under study were made according to the group affiliation from three different composite materials: Estelite Sigma Quick, Filtek Bulk Fill Posterior Restorative and DentLight. The bending strength was evaluated on the “MIP-10” testing machine of the company “NPK TECHMASH”. Determination of the surface hardness according to Vickers was carried out on the device PMT-3 of the company “LOMO”.According to laboratory studies, a statistically significant increase in flexural strength and surface hardness according to Vickers was determined for all samples of composite materials subjected to thermal vibration before polymerization.The data obtained indicate an increase in the strength characteristics of composite filling materials as a result of thermal vibration exposure before their polymerization, which increases the service life of composite fillings and reduces the risks of secondary caries formation after filling.
Publisher
Publishing House Belorusskaya Nauka
Reference21 articles.
1. Khabadze Z. S. Laboratory substantiation of the efficiency of pre-polymerization heating of nanocomposite material. Endodontiya today [Endodontics today], 2020, vol. 18, no. 1, pp. 15-20 (in Russian).
2. Wright M. C. Bulk and microscale composition analysis. Failure Analysis and Prevention. Materials Park, Ohio, 2021, pp. 85-91. https://doi.org/10.31399/asm.hb.v11.a0006759
3. Sevbitov A. V., Dan'shina S. D., Kuznetsova M. Yu., Platonova V. V., Borisov V. V. Icon as a method of choice for injectable treatment of initial caries in patients wiht ossifying progressive fibrodysplasia: a clinical case. Rossiiskii stomatologicheskii zhurnal [Russian journal of dentistry] , 2019, vol. 23, no. 6, pp. 280-283 (in Russian).
4. Shumilovich B. R., Leshcheva E. A., Kharitonov D. Yu., Morozov A. N., Saneev A. V. Change of the microstructure of enamel and dentin under the influence of the rotary tool in the treatment of caries (in vitro study)] . Rossiiskii stomatologicheskii zhurnal [Russian journal of dentistry], 2017, vol. 21, no. 2, pp. 68-71 (in Russian).
5. Muzyleva T. A. Modern adhesive systems in clinical dentistry. Studencheskii vestnik [Student bulletin], 2019, vol. 38-2 (88), pp. 21-22 (in Russian).