Abstract
Molten salts are an excellent choice for thermal energy storage materials in concentrated solar power (CSP) plants, yet some salts can cause corrosion of containment alloys that damage plants and increase maintenance costs. Corrosion rates have been characterized for many salt/alloy combinations. However, corrosion rates at junctions of dissimilar alloys in molten salts are relatively poorly characterized. At such junctions, which are common in CSP plants, it is possible that galvanic interactions or other mechanisms could increase corrosion above the industry standard of 20 µm/year. Preliminary reports measured corrosion at dissimilar alloy junctions with a variety of methods, but the results are not uniform. Additionally, some reports have shown that corrosion rates are higher for single alloys than for the same alloys when paired in a galvanic couple, suggesting complex corrosion mechanisms. Here we present a discussion on measuring galvanic corrosion in molten salts that accounts for differences in results between methods and explores the possibility of other mechanisms of corrosion in the system.
Funder
Solar Energy Technologies Office
Oak Ridge Institute for Science and Education
Advanced Materials and Manufacturing Technologies Office
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献