Effect of Torso Boundary Conditions on Spine Kinematic and Injury Responses in Head-First Impact Assessed with a 50th Percentile Male Human Body Model

Author:

Morgan M.I.1,Corrales M.1,Cripton P.2,Cronin D.S.1

Affiliation:

1. University of Waterloo, Canada

2. University of British Columbia, Canada

Abstract

<div>Computational and experimental studies have been undertaken to investigate injurious head-first impacts (HFI), which can occur during automotive rollovers. Recent studies assume a torso surrogate mass (TSM) boundary condition, wherein the first or first two thoracic vertebrae are potted and constrained to only move in the vertical loading direction. The TSM boundary condition has not been compared with a full body (FB) model computationally or experimentally for HFI. In this study, the Global Human Body Models Consortium 50th percentile male detailed human body model (M50-O, Version 6.0) was applied to compare the kinematic, kinetic, and injury response of an HFI with a TSM boundary condition (M50-TSM), and a full body boundary condition (M50-FB). Impacts (to M50-TSM and M50-FB) were simulated between the head and a rigid plate using a commercial FE code (LS-DYNA). The impact velocity of 3.1 m/s corresponded to the onset of spinal injury in diving reconstructions, and the impact velocity reported in experiments. The TSM boundary condition was simulated by applying a mass of 16 kg to the first thoracic vertebra (T1), and constraining motion to only the vertical direction. A quantitative comparison of the head and spine impact forces, spine kinematics, and prediction of hard tissue fracture was reported. The M50-TSM model demonstrated a 53.4% lower (straighter) spinal curvature 10 ms after impact, compared to the M50-FB. The lower curvature of the M50-TSM resulted in higher neck loads during that timeframe (2.26 kN M50-TSM, 1.44 kN M50-FB). The resulting hard tissue fracture in M50-TSM was attributed to direct compression at an early time (&lt;5 ms) in the impact, while M50-FB demonstrated compression-extension fractures later (&gt;16 ms) in the simulation. It was concluded that kinematics, kinetics, and injury response differed for the TSM and FB boundary conditions, and therefore these conditions are critical to consider when investigating HFI.</div>

Publisher

SAE International

Subject

Mechanical Engineering,Safety Research,Safety, Risk, Reliability and Quality,Human Factors and Ergonomics,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3