Author:
Tan Libin,Yuan Yuejin,Huang Can
Abstract
<div>The reasonable engine cooling system design can give a better cooling of engine,
the coolant flow direction and different cooling structure designs have great
impact on the cooling performance and fuel consumption of engine. Therefore, to
gain a deeper understanding of the impact of different cooling system designs on
engine cooling performance, three different split cooling structures and two
oil–water heat exchanger (OWHE) layouts are designed for a two-cylinder
motorcycle engine. Three-dimensional CFD analysis method is used for analyzing
the coolant velocity distributions and one-dimensional systematic analysis
method is used for analyzing the system flow rate at those cooling structure
designs and OWHE designs. Meanwhile, experimental investigation of different
cooling structures and OWHE layouts on fuel consumption is conducted by the
bench test of worldwide motorcycle test cycle. Results indicated that the
difference of coolant flow velocity distribution for four cooling structures are
small and the flow resistance of Case D is lowest at fully opened thermostat
condition. The fuel consumption of Case D is 4.78 L/100 km, 1.4% lower than that
of Case A with the fuel consumption 4.85 L/100 km. The combined split cooling
structure Case D and OWHE layout one is proven as the optimal cooling design
with 4% fuel consumption reduction compared with that of original cooling
structure Case A. The research results can provide theoretical reference for
engine cooling performance evaluation and give valuable data to motorcycle
designers for quick evaluation of design and quick solutions of improved
design.</div>
Subject
Fuel Technology,Automotive Engineering,General Earth and Planetary Sciences,General Environmental Science