Study of Flashing Flows Entering Evacuated Sampling Cylinders for Oil Circulation Rate Measurement in an Automotive Air Conditioning System

Author:

Haider Syed Angkan,Wang Xin,Elbel Stefan

Abstract

<div class="section abstract"><div class="htmlview paragraph">The oil circulation rate (OCR) is a deciding factor for the performance of automotive air conditioning systems at both the system and component levels. OCR is defined as the percentage by mass of oil present in a representative sample of oil-refrigerant mixture drawn from the system at steady state. In recent years, many industries are opting for low-OCR compressors, and so the OCR values are getting smaller, making it even more important to be able to accurately measure the OCR in the system. All the different OCR measurement techniques rely on the ASHRAE Standard 41.4 for proper calibration. This standard describes OCR measurement using a sampling technique which involves connecting an evacuated sampling cylinder at the liquid line of the system at steady state to draw a sample containing the liquid mixture of refrigerant and oil. However, several factors such as orientation of sampling cylinder and valve opening speed can affect the OCR results. The flow entering the sampling cylinder initially consists of both liquid refrigerant and liquid oil. As the valve on the sampling cylinder is opened, the refrigerant undergoes flashing followed by recompression and re-condensation of vapor refrigerant, and simultaneous filling up with liquid mixture until pressure equalization between the system supply line and evacuated sampling cylinder is achieved. This two-phase, two-component, phase changing flow is complex, and for the present study, flow visualization using a high-speed camera and analytical tools are used to study the flashing flow of pure refrigerant entering an evacuated sampling cylinder. The obtained results are used to compare with those obtained with oil-refrigerant mixture to shed light on how parameters such as sampling cylinder orientation and valve opening speed can affect the measured OCR values.</div></div>

Publisher

SAE International

Reference17 articles.

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3