Author:
Haider Syed Angkan,Wang Xin,Elbel Stefan
Abstract
<div class="section abstract"><div class="htmlview paragraph">In automotive air conditioning systems, the oil circulation rate (OCR) is known to affect performance at both the component and system levels. The OCR is the ratio of the mass of the oil in a representative sample of oil-refrigerant mixture from the system to the total mass of the sample taken during steady state operation. With the general industry trend towards low-OCR compressors, the OCR values of interest are getting smaller, and it is becoming increasingly important to acquire an accurate knowledge of OCR for proper system optimization. While there are different OCR measurement techniques available, they all require accurate calibration which is done using the ASHRAE Standard 41.4. The standard describes a sampling technique using an evacuated sampling cylinder with a dead end to draw a sample of oil-refrigerant mixture from the system liquid line. The standard, however, doesn’t specify parameters such as sampling cylinder orientation, valve opening speed, etc. which can potentially affect the measured OCR. For the present study, the OCR is measured in an automotive air conditioning facility that uses R-134a as refrigerant and PAG ISO 46 oil as the lubricant for the electric scroll compressor used. OCR results obtained from sampling with both flow-through and evacuated type sampling cylinders are compared at different compressor speeds, and the discrepancies between the results are discussed. For the sampling technique described by the ASHRAE Standard, the OCR is measured with the evacuated sampling cylinder at different orientations and valve opening speeds, and obtained results revealed significant discrepancy between the OCR values. High-speed camera flow visualizations at the evacuated sampling cylinder entrance were also taken, and the observed flows supported the trend in the OCR results.</div></div>
Reference12 articles.
1. Radermacher , R. ,
Cremaschi , L. , and
Schwentker , R.A.
Modeling of Oil Retention in the Suction Line and Evaporator of Air-Conditioning Systems HVAC&R Research 12 1 2006 35 56 10.1080/10789669.2006.10391166
2. Youbi-Idrissi , M. and
Bonjour , J.
The Effect of Oil in Refrigeration: Current Research Issues and Critical Review of Thermodynamic Aspects International Journal of Refrigeration 31 2 2008 165 179 10.1016/j.ijrefrig.2007.09.006
3. Shen , B. and
Groll , E.A.
A Critical Review of the Influence of Lubricants on the Heat Transfer and Pressure Drop of Refrigerants, Part 1: Lubricant Influence on Pool and Flow Boiling HVAC&R Research 11 3 2005 341 359 10.1080/10789669.2005.10391142
4. Liu , X. and
Hrnjak , P.
Oil Effects on Performance of Automobile A/C system Proceedings of the International Refrigeration and Air Conditioning Conference 2016 1672 West Lafayette, IN, USA
5. Wang , X. ,
Haider , S.A. ,
Hrnjak , P. and
Elbel , S.
Transient Migration of Oil at Compressor Discharge and Suction During Startup Proceedings of the International Refrigeration and Air Conditioning Conference 2022 2266 West Lafayette, IN, USA
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献