The Effect of Clinical Characteristics and Stent Parameters on Left Ventricular Mechanical Dyssynchrony

Author:

Mostafa S.1ORCID,Sanad O.1ORCID,Shawky M.1ORCID,Magdy M.1ORCID,Elkeshk E.1ORCID

Affiliation:

1. Benha University

Abstract

Aim. To study short term effect of stent size and number on left ventricular mechanical dyssynchrony after elective percutaneous coronary intervention (PCI) to left anterior descending (LAD) artery.Materials and methods. the study included 150 adult patients with LAD lesion treated with PCI using drug-eluting stent. Patients were evaluated pre PCI then 1 month and 3 months post PCI for evaluation of mechanical dyssynchrony using tissue synchronization image (TSI).Results. Before revascularization mean left ventricular ejection fraction was 51.2±5.7 %, mean time to peak TSI was 213.6±10.9 ms; 1 month after PCI TSI improved significantly to 163.7±17.6 ms (p<0.001), 3 months after PCI showed more improvement to 120.7±26.9 ms (p<0.001). After 3m; 61 patients (40.7%) showed recovery to normal TSI value. The predictors of non-improvement of time to peak TSI after 3 months were diabetes mellitus (p=0.007), dyslipidemia (p=0.001) and stent length (p=0.001), number of stents (p=0.004). There were strong negative correlation between stent length and improvement of the time to peak TSI at 1 month (r=-0.352, p<0.001) and at 3 months (r=-0.509, p<0.001),and also with number of stent at 1 month (r= -0.173, p=0.034) and at 3 months (r=-0.499, p<0.001), but the correlation between stent diameter and improvement of the TSI wasn’t significant neither at 1 month nor at 3 months (r=0.055, p=0.504 and r= -0.018, p=0.827) respectively.Conclusion. Increased number and length of the implanted stents were predictors to non-improvement of mechanical dyssynchrony, while stent diameter didn’t affects the recovery.

Publisher

Stolichnaya Izdatelskaya Kompaniyaizdat

Subject

Pharmacology (medical),Cardiology and Cardiovascular Medicine

Reference17 articles.

1. Čelutkienė J, Plymen CM, Flachskampf FA, et al. Innovative imaging methods in heart failure: a shifting paradigm in cardiac assessment. Position statement on behalf of the Heart Failure Association of the European Society of Cardiology. Eur J Heart Fail. 2018;20(12):1615-33. DOI:10.1002/ejhf.1330.

2. Rihal CS, Naidu SS, Givertz MM, et al. 2015 SCAI/ACC/HFSA/STS Clinical Expert Consensus Statement on the Use of Percutaneous Mechanical Circulatory Support Devices in Cardiovascular Care: Endorsed by the American Heart Assocation, the Cardiological Society of India, and Sociedad Latino Americana de Cardiologia Intervencion; Affirmation of Value by the Canadian Association of Interventional Cardiology-Association Canadienne de Cardiologie d'intervention. J Am Coll Cardiol. 2015;65(19):e7-e26. DOI:10.1016/j.jacc.2015.03.036.

3. Yasir A, Noor L, Dar M, et al. Impact of stent length and diameter on short term clinical outcomes of drug eluting stents in patients with stable coronary artery disease. Pak J Med Sci. 2017;33(4):959-62. DOI:10.12669/pjms.334.13068.

4. Yu CM, Lin H, Zhang Q, et al. High prevalence of left ventricular systolic and diastolic asynchrony in patients with congestive heart failure and normal QRS duration. Heart. 2003;89(1):54-60. DOI:10.1136/heart.89.1.54.

5. Lee PW, Zhang Q, Yip GWK, et al. Left ventricular systolic and diastolic dyssynchrony in coronary artery disease with preserved ejection fraction. Clin Sci (Lond). 2009;116(6):521-9. doi: 10.1042/CS20080100.