Author:
Stravinskas Mindaugas,Nilsson Malin,Horstmann Peter,Petersen Michael Mørk,Tarasevicius Sarunas,Lidgren Lars
Abstract
Abstract. Objectives: The objective is to present the antibiotic elution from a locally implanted gentamicin containing hydroxyapatite and calcium sulphate bone substitute with an extended follow up of 30 days.We also compare the pharmacokinetics of the ceramic bone substitute with a published study on gentamicin containing poly (methyl methacrylate) (PMMA) bone cement used in primary total hip arthroplasty.Methods: Gentamicin release was measured in the urine for a month and the serum for 4 days in 10 patients operated for trochanteric hip fractures and 10 patients in uncemented hip revisions. 17 patients were followed up at one year and 3 patients at 6 months.Results and Discussion: The gentamicin concentrations measured in serum were low and approximately 100 times less than in urine during the first days, indicating high local concentrations at the implant site. The elution from the biphasic bone substitute showed a stronger burst and higher gentamicin concentrations for the first week compared to that reported for PMMA used in hip arthroplasty. Also, for the bone substitute a complete gentamicin elution was obtained after 30 days, while for the PMMA cement sub-inhibitory MIC levels of gentamicin were still present in urine 60 days past surgery. No infections were detected.Conclusions: A new biphasic bone substitute containing antibiotics could potentially be used to prevent infection in patients treated for trochanteric hip fractures or uncemented hip revisions. The gentamicin elution from the bone substitute is efficient with high initial local gentamicin concentrations and complete release at 30 days.
Subject
Infectious Diseases,Orthopedics and Sports Medicine,Surgery
Reference17 articles.
1. Cancienne JM, Tyrrell Burrus M, Weiss DB, Yarboro SR. Applications of Local Antibiotics in Orthopedic Trauma. Orthop Clin North Am. 2015;46(4):495–510.
2. Abramo A, Geijer M, Kopylov P, Tägil M. Osteotomy Of Distal Radius Fracture Malunion Using a Fast Remodelling Bone Substitute Consisting of Calcium Sulphate and Calcium Phosphate. J Biomed Mater Res B Appl Biomater. 2010;92B:281–286.
3. Karr J. Clinical Case Presentation: Metatarsal Delayed Union Management in a Diabetic Patient with CERAMENT™|BONE VOID FILLER. The Journal of Diabetic Foot Complications. 2010;2(3):65–68. [Google Scholar]
4. Iundusi R, Gasbarra E, D'Arienzo M, Piccioli A, Tarantino U. Augmentation of tibial plateau fractures with an injectable bone substitute: CERAMENT™. Three year follow-up from a prospective study. BMC Musculoskeletal Disord. 2015;16:115. [PMC free article]
5. Nilsson M, Wang J-S, Wielanek L, Tanner KE, Lidgren L. Biodegradation and biocompatibility of a calcium sulphate-hydroxyapatite bone substitute. J Bone Joint Surg [Br] 2004;86B:120–125.