Carbon nanotube-based multiple source C-arm CT system: feasibility study with prototype system

Author:

Moon Seunghyuk1,Kang Jungsu2,Kim Youngkwang2,Jo Eunha2,Jeong Pilsoo2,Roh Youngjun2,Baek Jongduk3

Affiliation:

1. Yonsei University

2. KohYoung Technology

3. Bareunex Imaging

Abstract

To extend the field of view while reducing dimensions of the C-arm, we propose a carbon nanotube (CNT)-based C-arm computed tomography (CT) system with multiple X-ray sources. A prototype system was developed using three CNT X-ray sources, enabling a feasibility study. Geometry calibration and image reconstruction were performed to improve the quality of image acquisition. However, the geometry of the prototype system led to projection truncation for each source and an overlap region of object area covered by each source in the two-dimensional Radon space, necessitating specific corrective measures. We addressed these problems by implementing truncation correction and applying weighting techniques to the overlap region during the image reconstruction phase. Furthermore, to enable image reconstruction with a scan angle less than 360°, we designed a weighting function to solve data redundancy caused by the short scan angle. The accuracy of the geometry calibration method was evaluated via computer simulations. We also quantified the improvements in reconstructed image quality using mean-squared error and structural similarity. Moreover, detector lag correction was applied to address the afterglow observed in the experimental data obtained from the prototype system. Our evaluation of image quality involved comparing reconstructed images obtained with and without incorporating the geometry calibration results and images with and without lag correction. The outcomes of our simulation study and experimental investigation demonstrated the efficacy of our proposed geometry calibration, image reconstruction method, and lag correction in reducing image artifacts.

Funder

National Research Foundation of Korea

Publisher

Optica Publishing Group

Subject

Atomic and Molecular Physics, and Optics

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3