PLTP in situ measurement method of Wolter-I type mandrel

Author:

Wu Kaiji,Ding Fei,Wu Dongxu1,Huang Yuejia,Qiao Zheng,Wang Bo

Affiliation:

1. Genertec Machine Tool Engineering Research Institute Co., Ltd.

Abstract

Wolter-I type grazing incidence focusing mirrors are widely used for imaging applications in the field of x-ray astronomy. In an electroforming replication process, the accuracy of a mirror is directly determined by the mandrel. A portable long trace profiler (PLTP) is developed and implemented to measure the generatrix error of the Wolter-I type mandrels on an ultra-precision machine tool. The measurement accuracy is confirmed via optical flat measurement experiment. Two PLTP in situ measurement methods, pentaprism scanning and direct scanning, are studied. The comparison of the methods and the corresponding measurement errors are analyzed and discussed. The necessity of PLTP measurement in evaluating optical performance is illustrated through three-dimensional ray tracing.

Funder

National Natural Science Foundation of China

National Key Research and Development Program of China

High Quality Development Project

State Key Laboratory of Mechanical System and Vibration

Publisher

Optica Publishing Group

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370