Author:
Awerkamp Parker A.,Hill David,Fish Davin,Wright Kimi,Bashaw Brandt,Nordin Gregory P.,Camacho Ryan M.
Abstract
We present a method of maintaining a water microdroplet resonator using a 3D printed microfluidic system, which operates in an ambient environment and allows for quality factors as high as 200 million.