Affiliation:
1. Universities of Shaanxi Province
2. Northwest University
Abstract
We propose a sensitivity-enhanced fiber Bragg grating (FBG) magnetic
field sensor for magnetic flux leakage (MFL) detection. The testing
system consists of the FBG, suspended strain concentration structure,
and two ceramic tubes bonded on a Terfenol-D base. We show the
relation between the MFL and the width and depth of the crack, the
lift-off of the sensor away from the surface of the workpiece, and the
angle between the orientation of the sensor and the magnetization
direction. The experimental results are very consistent with those
obtained from finite element analysis simulations. The sensitivity of
the sensor is increased to 81.11 pm/mT for increasing magnetic
fields and 91.55 pm/mT for decreasing magnetic fields. The MFL
test demonstrates that the sensor can identify a crack with a width of
0.5 mm and depth of 2 mm in an 8 mm thick
workpiece. To the best of our knowledge, the magnetic field sensor
proposed in this work has the highest sensitivity compared with the
same types of sensors. Moreover, the application of an FBG-Terfenol-D
based magnetic field sensor in the MFL test shows good performance.
Compared with traditional electrical MFL testing technologies, the
sensitivity-enhanced optical fiber magnetic field sensor has a higher
resolution and longer survival time in harsh environments.
Funder
National Natural Science Foundation of
China
Subject
Atomic and Molecular Physics, and Optics,Engineering (miscellaneous),Electrical and Electronic Engineering