Biocompatibility and radiosensitivity of a fiber optical-based dosimeter: biological applications

Author:

Elsharkawi Adel S. A.1,Elazab Huda A.2,Askar Mostafa A.3,Abdelrahman Ibrahim Y.3,Arafa Amany A.1ORCID,Gomma Lofty R.4,Lo Yu-Lung

Affiliation:

1. National Center for Radiation Research and Technology (NCRRT), Egyptian Atomic Energy Authority

2. Egyptian Atomic Energy Authority

3. National Centre for Radiation Research and Technology (NCRRT), Egyptian Atomic Energy Authority (EAEA)

4. Banha University

Abstract

This study introduces a cutting-edge fiber-optic dosimetry (FOD) sensor designed for measuring radiation in biological settings. The accuracy and precision of dosimeters for small animals, particularly prolonged exposure to nonuniform radiation fields, are always challenging. A state-of-the-art in-vivo dosimeter utilizing glass-encapsulated Thermoluminescence cylindrical detector (TLD) was introduced. The FODs are implanted into the rat during a prolonged irradiation scenario involving 137Cs where the rat has the freedom to move within a heterogeneous radiation domain. The implantation surgery was verified with X-ray computed tomography (CT) in addition to biochemical and pathological tests to assess the biocompatibility of FOD in vivo. A versatile FOD is designed for industrial and medical fields, which demand accurate and resilient radiation dosimeters. The dose measurements are associated with precise two-dimensional (2D) radiation distribution imaging. Three cylindrical FODs and three standards TLD_100 for each rat were tested. The measurements of peak irradiation before and after exposure reveal greater stability and superior sensitivity when compared to standard thermo-luminescence detectors in an in-vivo animal test. To the best of our knowledge, FOD testing on live animals is presented for the first time in this paper. Regarding the safety and biocompatibility of FOD, no morphological signs with any kind of inflammation or sensitivity toward the FOD material have been remarked. Moreover, with the current FOD, there is no oedema between the epidermal, dermal, and subdermal sections at the site of implantation. The results also show the stable levels of white blood cells (lymphocytes, granulocytes, MID) as blood inflammatory markers before surgery and at the time of extraction of the implanted dosimeters, thus confirming the biocompatibility for each optical fiber cylinder dosimeter. As a result, the new dosimeters have excellent biocompatibility in living tissues and have 100% accurate reusability intensity of the delivered radiation doses compared to TLD_100 which demonstrated a 45% reduction in its intensity accuracy.

Funder

National Science and Technology Council

Publisher

Optica Publishing Group

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3