Affiliation:
1. Foshan Electrical and Lighting Co. Ltd
2. Zhongshan – Fudan Joint Innovation Center
Abstract
Quantitative evaluation of spatial brightness has been difficult, mainly due to the lack of a metric that is both highly related to subjective evaluation and convenient to measure in the field. This work investigated the applicability of using indirect corneal illuminance to evaluate spatial brightness for a visual field in interior spaces. Three lighting scenes with different patterns of lighting distribution, which all delivered indirect light to the subjects, were compared against each other in pairs for spatial brightness. The corresponding indirect corneal illuminance required for each test scene to match the spatial brightness of the reference scene with a fixed corneal illuminance was obtained. The results showed that our proposed metric had a high correlation with subjective evaluation of spatial brightness even under very different patterns of lighting distribution. Furthermore, the proposed metric was compared with the prior metrics of MRSE and Lav,B40 in spatial brightness evaluation, and the former showed the best correlation with subjective judgments. Since the spatial brightness assessment for various visual fields together compose people’s overall impression of an illuminated space, the proposed metric of indirect corneal illuminance, which combines both accuracy and convenience in measurement, could serve as a preferred metric for spatial brightness evaluation.
Funder
National Natural Science Foundation of China
Subject
Atomic and Molecular Physics, and Optics
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献