Polarization-dependent LIF/Mie ratio for sizing of micrometric ethanol droplets doped with Nile red

Author:

Koegl Matthias123,Dai Hongfei1,Baderschneider Kevin1,Ulrich Hannah123,Zigan Lars123

Affiliation:

1. Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU)

2. FAU

3. Universität der Bundeswehr München (UniBw M)

Abstract

The present study deals with droplet sizing based on laser-induced fluorescence (LIF) and Mie scattering for varied polarization of the utilized laser (parallel or perpendicular). The polarization-dependent LIF/Mie ratio is studied for micrometric droplets (25–60 µm) produced with a droplet generator. The investigations were carried out with the dye Nile red dissolved in ethanol and ethanol/iso-octane mixtures. A spectral absorption and fluorescence characterization at various dye and ethanol concentrations is carried out in a cuvette in order to identify reabsorption effects. The L I F | | droplet images (index | | : parallel polarization) show a more homogeneous intensity distribution in the droplets and slightly stronger morphology-dependent resonances (MDRs) in comparison to L I F (index : perpendicular polarization). The spectral LIF emissions reveal a dependence of the MDR on the ethanol admixture. The larger the ethanol content, the lower the MDR peak, which is also shifted further to the red part of the spectrum. The Mie droplet signal images are mainly characterized by two distinct glare points, one at the entrance of the laser light (reflection) and one at the exit (first-order refraction). The M i e images show a more pronounced entrance glare point, in comparison to M i e | | , where the exit glare point is more pronounced. These observations are in accordance with the theory. The calibration curve of the micro droplet signals revealed a volumetric trend of the LIF signals and a slightly higher L I F signal and sensitivity in comparison to L I F | | . The signal M i e follows roughly a quadratic trend on average, while M i e | | follows a linear trend. Consequently, the calculated L I F / M i e ratio shows a linear trend, whereas the L I F | | / M i e | | ratio shows a quadratic trend, which confirms theoretical calculations. A numerical simulation of the Mie signal at various detection angles shows a good agreement with the experimental data at large apertures.

Publisher

Optica Publishing Group

Subject

Atomic and Molecular Physics, and Optics,Engineering (miscellaneous),Electrical and Electronic Engineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3