Abstract
Miniature acoustic sensors with high sensitivity are highly desired for applications in medical photoacoustic imaging, acoustic communications and industrial nondestructive testing. However, conventional acoustic sensors based on piezoelectric, piezoresistive and capacitive detectors usually require a large element size on a millimeter to centimeter scale to achieve a high sensitivity, greatly limiting their spatial resolution and the application in space-confined sensing scenarios. Herein, by using single-crystal two-dimensional gold flakes (2DGFs) as the sensing diaphragm of an extrinsic Fabry-Perot interferometer on a fiber tip, we demonstrate a miniature optical acoustic sensor with high sensitivity. Benefiting from the ultrathin thickness (∼8 nm) and high reflectivity of the 2DGF, the fiber-tip acoustic sensor gives an acoustic pressure sensitivity of ∼300 mV/Pa in the frequency range from 100 Hz to 20 kHz. The noise-equivalent pressure of the fiber-tip acoustic sensor at the frequency of 13 kHz is as low as 62.8 µPa/Hz1/2, which is one or two orders of magnitude lower than that of reported optical acoustic sensors with the same size.