Deep learning on photoacoustic tomography to remove image distortion due to inaccurate measurement of the scanning radius

Author:

Mondal Sudeep,Paul Subhadip,Singh Navjot,Saha Ratan KORCID

Abstract

Photoacoustic tomography (PAT) is a non-invasive, non-ionizing hybrid imaging modality that holds great potential for various biomedical applications and the incorporation with deep learning (DL) methods has experienced notable advancements in recent times. In a typical 2D PAT setup, a single-element ultrasound detector (USD) is used to collect the PA signals by making a 360° full scan of the imaging region. The traditional backprojection (BP) algorithm has been widely used to reconstruct the PAT images from the acquired signals. Accurate determination of the scanning radius (SR) is required for proper image reconstruction. Even a slight deviation from its nominal value can lead to image distortion compromising the quality of the reconstruction. To address this challenge, two approaches have been developed and examined herein. The first framework includes a modified version of dense U-Net (DUNet) architecture. The second procedure involves a DL-based convolutional neural network (CNN) for image classification followed by a DUNet. The first protocol was trained with heterogeneous simulated images generated from three different phantoms to learn the relationship between the reconstructed and the corresponding ground truth (GT) images. In the case of the second scheme, the first stage was trained with the same heterogeneous dataset to classify the image type and the second stage was trained individually with the appropriate images. The performance of these architectures has been tested on both simulated and experimental images. The first method can sustain SR deviation up to approximately 6% for simulated images and 5% for experimental images and can accurately reproduce the GTs. The proposed DL-approach extends the limits further (approximately 7% and 8% for simulated and experimental images, respectively). Our results suggest that classification-based DL method does not need a precise assessment of SR for accurate PAT image formation.

Funder

Indian Council of Medical Research

Department of Biotechnology, Ministry of Science and Technology, India

Publisher

Optica Publishing Group

Subject

Atomic and Molecular Physics, and Optics,Biotechnology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3